Pro-face GP-4402WW (part of the GP4000E series) is a 7-inch widescreen HMI by Schneider Electric that primarily utilizes the
software suite for screen editing and communication configuration Pro-face by Schneider Electric Core Software: GP-Pro EX The standard software used to program this unit is
, a versatile development environment for creating HMI and PLC projects. Pro-face by Schneider Electric Version Compatibility : The GP-4402WW is supported starting from GP-Pro EX Ver. 4.03.400 Essential Model Enablement
: In many versions of GP-Pro EX (including 4.09), the GP-4402WW model may not be visible in the initial project selection. To enable it, you must run a specific hidden patch file while the software is closed: C:\Program Files (x86)\Pro-face\GP-Pro EX 4.0x\OP\ Files to Run YTSetup.exe YTPartsLCSetup.exe Requirement
: You may need to enable "Show hidden files" in Windows Explorer to see these files. Schneider Electric Software Features & Capabilities Driver Support
: The software allows the GP-4402WW to communicate via multiple protocols, including MODBUS TCP, CANopen Slave, and various PLC-specific drivers. Virtual Backup Memory
: Since the GP-4402WW lacks physical SRAM (backup memory), the software manages a "virtual backup memory" area within the unit's internal FLASH EPROM to store alarm history and filing data. Migration Support GP-Pro EX Ver. 5.01 includes tools like the Project Converter
to migrate older projects from GP-PRO/PBIII C-Package to the newer environment. Pro-face by Schneider Electric Technical Resources & Downloads
For official drivers, manuals, and software updates, you can use the Pro-face GP4000E Support Page
The GP-4402WW is a 7-inch widescreen HMI from Pro-face’s GP4000E series. To program and manage this device, you must use the GP-Pro EX software. While modern versions of the software support this model, users often encounter issues where the model name does not appear in the selection menu, requiring specific patches or installation steps. Core Software: GP-Pro EX
GP-Pro EX is the premier development software for Pro-face HMIs, offering a unified platform for screen design and logic programming.
Version Compatibility: The GP-4402WW is officially supported from GP-Pro EX Version 4.04 and later.
Key Features: It allows for recipe management, alarm logging, and integrated energy monitoring. It also supports internal logic programming (ladder diagrams), which can help reduce the processing load on your PLC.
Virtual Testing: For those without physical hardware, the software includes WinGP, which can act as a virtual HMI on a PC for up to three hours at a time for testing and verification. Enabling the GP-4402WW Model
A common issue for engineers is that the GP-4402WW (or its companion GP-4502WW) remains hidden even in newer software versions like 4.07 or 4.09. To fix this, you must run a specific model-addition patch found in your installation folder:
Close GP-Pro EX: The patch will not work if the software is running.
Locate the Patch: Navigate to your installation directory (typically C:\Program Files (x86)\Proface\GP-Pro EX 4.0\OP\). gp-4402ww software
Run Installer Files: Double-click YTSetup.exe and YTPartsLCSetup.exe.
Note: These may be hidden files, so ensure your Windows Explorer settings are set to "Show hidden files and folders".
Restart Software: Once these brief background processes finish, the GP-4402WW model should appear under the GP4000E series in the device selection menu.
The Pro-face GP-4402WW Go to product viewer dialog for this item.
(model PFXGP4402WADW) is a 7-inch standard widescreen human-machine interface (HMI) designed for industrial automation applications. It is part of the Pro-face GP4000E series. The software required to program, configure, and communicate with this touchscreen unit is GP-Pro EX, a comprehensive screen editor software provided by Pro-face (by Schneider Electric). This article provides an in-depth guide to the
software, focusing on installation, features, and troubleshooting. 1. What is GP-Pro EX Software?
GP-Pro EX is the industry-standard software used to develop screen applications for Pro-face HMIs. It allows engineers to: Create intuitive, high-quality 3D graphical interfaces.
Configure communication drivers for various PLCs, robots, and controllers (e.g., Modbus, Siemens, Mitsubishi). Develop complex logic using Ladder Language or D-Script.
Simulate the HMI project directly on a PC without needing physical hardware. 2. Software Compatibility and Requirements is a modern HMI, requiring GP-Pro EX version 4.03 or later.
Version Recommendation: It is highly recommended to use GP-Pro EX Ver. 4.09 or later for the best support, including 64-bit operating system compatibility. Virtual Backup Memory: Note that the
does not have physical SRAM. The software manages virtual backup memory for saving alarm histories and recipes to the internal flash memory. 3. Installation Guide and Enabling the Go to product viewer dialog for this item. Sometimes, even with a newer version of GP-Pro EX, the
model might not appear in the selection list. Follow these steps to enable it: Install GP-Pro EX 4.0x or later.
Navigate to the installation folder (typically C:\Program Files (x86)\Pro-face\GP-Pro EX 4.0x\OP).
Run YTSetup.exe as an administrator. This runs a background process to add new models.
Restart the GP-Pro EX software. The GP-4402WW or PFXGP4402WADW option should now be visible. 4. Key Features of GP-4402WW Software
The software provides powerful tools to maximize the efficiency of the 7-inch widescreen display: Pro-face GP-4402WW (part of the GP4000E series) is
Easy Screen Creation: Features ready-made 3D parts, including switches, lamps, and meters, which enhance visual recognition on the factory floor.
Data Monitoring & Sampling: The software allows you to log data (temperature, pressure, etc.) and display it via trends or csv files, which can be stored on a USB drive.
Alarm Analysis: Allows operators to touch an alarm message to immediately see the cause and related data in chronological order.
Language Support: Easily create multi-language projects to meet global manufacturing needs.
Remote Access: The software allows for the configuration of "Pro-face Connect" or "GP-Viewer EX," which provides secure, remote monitoring and control of the HMI from a PC, tablet, or smartphone. 5. Troubleshooting and Tips
"Unable to load project" error: This usually happens if the project was created with a newer version of the software than you are running. Ensure your GP-Pro EX is updated to the latest version.
Model Not Found: Rerun the YTSetup.exe tool as described above.
Transfer Issues: Make sure to select the correct communication port (USB or Ethernet) in the transfer settings.
/GP-Pro EX combination is a versatile, user-friendly solution, offering robust functionality for both simple monitoring and complex control tasks. To give you the most helpful advice, could you tell me: Which version of Windows are you running this on? What PLC are you trying to connect to?
With these details, I can tell you exactly which patch or setting you need. Softwre required for Proface HMI GP4402-WW - PLCtalk.net
This is the only software officially used to create, edit, and transfer projects to the GP-4402WW.
Key Features within GP-Pro EX for this model:
If you need to connect the HMI to SCADA software (like Ignition, WinCC, or FactoryTalk), the Pro-face OPC Server acts as a bridge. It allows the SCADA system to read tags directly from the GP-4402WW’s memory.
Despite its reliability, you may encounter these common software-related problems:
| Symptom | Likely Software Cause | Fix |
| :--- | :--- | :--- |
| "Project file is corrupted" | Power loss during transfer | Re-transfer project with "Verify after transfer" enabled. |
| PLC tags show "####" | Driver not started or tag address mismatch | In Offline Mode → "Start I/O Driver" manually. |
| Transfer freezes at 50% | Firewall blocking GP-Pro EX | Disable Windows Defender or add TransTool.exe to exceptions. |
| HMI boot loops | Wrong System Program version | Perform a "Clear All Data" from bootloader menu, then reload OS. |
The GP-4402WW is a powerhouse of reliability, but its software—GP-Pro EX—is the engine that drives it. By understanding the difference between the development environment, the transfer tool, and system drivers, you can significantly reduce downtime and unlock advanced automation features. Heat Output: It glows a bright
Whether you are creating a complex batch control system or simply replacing a broken screen, ensuring you have the correct version of the software and proper drivers is essential. Always download from official channels, keep your firmware updated, and leverage the massive driver library to connect to virtually any PLC on the market.
Call to Action: Have a specific question about a GP-4402WW software error? Leave a comment below or contact Pro-face technical support with your GP-Pro EX version number ready.
Keywords used: gp-4402ww software, Pro-face GP-Pro EX, GP4402WW driver, HMI programming, transfer tool, industrial automation, Schneider Electric HMI.
The GP-4402WW is a 7.5-inch widescreen HMI from Pro-face’s GP4000E series. To program or configure this device, you must use the GP-Pro EX software. 1. Required Software & Compatibility
The GP-4402WW requires a specific version range of the GP-Pro EX editor to function correctly:
Minimum Version: Supported from GP-Pro EX Ver. 4.03.400 or later.
Recommended Versions: Versions like V4.06.200 or V4.09 are commonly used for this model.
Activation Patch: In some cases, even with Ver. 4.09, the model may not appear in the selection list. You may need to run a hidden patch located at: C:\Program Files (x86)\Pro-face\GP-Pro EX 4.09\OP\YTSetup.exe to enable the GP4000E models. 2. How to Obtain the Software
You can download the software directly from the Pro-face Support / Downloads page.
It is important to note that you cannot use older Pro-face software for the GP-4402WW:
If you are maintaining a very old system, ensure you are using GP-Pro EX V3.0 or later.
Beyond GP-Pro EX, several smaller software tools are critical for daily work:
| Software | Purpose | | :--- | :--- | | Pro-face Transfer Tool | Standalone utility for batch transfers (faster than GP-Pro EX for large deployments). | | GP-Pro EX Recipe Editor | Edit CSV-based recipe data offline and upload to the HMI. | | GP-Pro EX Logic Designer | Allows the GP-4402WW to run ladder logic (yes, it has a soft-PLC feature). Use sparingly—CPU is limited. | | Backup Tool (SD card) | From the HMI's offline menu, you can backup both the system OS and project to a FAT32-formatted SD card. No external software needed. |
The GP-4402WW can act as a simple FTP server (enabled via GP-Pro EX system settings). You can use any FTP client (like FileZilla) to upload recipe CSV files or download historical alarms without stopping production.
Rating: 5/5