Manual | Sinotimer Tm-630s

Sinotimer TM-630S is a heavy-duty, 7-day programmable digital timer designed to control high-load electrical equipment (up to 30 Amps / 5000 Watts ). Unlike the standard TM-630A, the "S" model features second-interval timing

, making it ideal for precision tasks like irrigation pumps or industrial signals. Digital Zakka 1. Key Specifications Load Capacity : 30A 250V AC (Resistive). Timing Range : 1 second to 168 hours. : Up to 28 ON/OFF settings per day. Backup Power

: Built-in 3V battery to retain settings during power outages. : Auto time error correction ( plus or minus 30 seconds weekly). Digital Zakka 2. Button Functions P (Program) : Enter or review timing programs.

: Set the day of the week (supports 15 combinations of daily programs). H+ / M+ / S+ : Adjust hours, minutes, and seconds. circled dot : Used with other buttons to set the current time. MANUAL (C/R) : Switch between modes; also used to lock/unlock the keypad. : Clear all settings (usually a small recessed button). 3. Setup Instructions Setting the Current Time circled dot While holding, press until the correct day is shown. to set the current hour, minute, and second. Release the button to save. Programming ON/OFF Events . The screen will show "1 ON".

to select the day(s) the program should run (e.g., specific days, weekends, or daily). to set the exact start time. again to set "1 OFF". Repeat steps 2-3 to set the stop time. circled dot button to exit and save. Yueqing Xinyang Technology Co., Ltd. Operating Modes button to cycle through: : Load is permanently powered. : Load is permanently disconnected. : Load follows your programmed schedule. 4. Safety & Wiring

The SINOTIMER TM-630S is a professional-grade, 7-day digital programmable timer switch designed for industrial and domestic automation. Unlike standard timers, the TM-630S supports 1-second interval precision, making it ideal for tasks requiring short, high-frequency bursts of power, such as school bells, factory sirens, or complex irrigation systems. Key Technical Specifications

The TM-630S is available in several voltage variants (e.g., 110V, 220V, or 12V DC) to suit different power requirements.

Load Capacity: Supports high loads up to 30 Amps (approximately 5000 Watts). Programming: Up to 28 ON/OFF daily or weekly programs. Minimum Interval: 1 second.

Power Reserve: Integrated 3V rechargeable battery retains programs for up to 60–90 days during power outages. Installation: Designed for panel or wall mounting. Initial Setup: Unlocking and Time Sync

Before programming, the device often locks itself to prevent accidental changes.

Battery Backup: Internal battery keeps settings for up to 90 days during blackouts. Step-by-Step Programming Guide 1. Unlock the Device The device often auto-locks to prevent accidental changes. Action: Press the C/R (Cancel/Recall) button 4 times.

Visual Check: The "a" or lock symbol on the screen will disappear. 2. Setting the Current Time Clock: Hold the Clock (circle icon) button.

Day: While holding Clock, press D+ to select the current day of the week. sinotimer tm-630s manual

Time: While holding Clock, press H+ (Hour) and M+ (Minute) to set the current time. 3. Setting ON/OFF Programs

Press the P (Timer) button once. You will see "1 ON" on the screen.

Press D+ to choose the days of the week (e.g., Daily, Weekdays, or Weekends). Press H+, M+, and S+ (Second) to set the exact start time.

Press P again to see "1 OFF." Repeat the steps to set the time the device should turn off. Press Clock to exit and save. 4. Manual Overide

If you need to flip the switch immediately without waiting for a program:

Press the Manual button to cycle through ON, AUTO, and OFF states.

Ensure it is set to AUTO if you want your programmed schedules to run. Wiring & Safety Tips

The TM-630S is typically panel or wall-mounted. It comes in two primary voltage variants: TM630S-1: Operates on 100–130V. TM630S-2: Operates on 200–250V.

For detailed wiring diagrams and technical diagrams, you can refer to the Sinotimer Operating Manual provided by Pic-Control or the official documentation on Manuals.plus. sinotimer-tm-630a-operating-manual.pdf - pic-control

Introduction

The Sinotimer TM-630S is a digital timer controller designed for various industrial and commercial applications. This manual provides a detailed guide on the installation, operation, and maintenance of the TM-630S timer.

Overview of the TM-630S

The TM-630S is a microprocessor-based timer that offers a wide range of features, including:

Installation

  1. Unpacking and Inspection: Carefully unpack the TM-630S and inspect for any damage or defects.
  2. Mounting: Mount the TM-630S on a standard 35mm DIN rail or on a flat surface using the provided screws.
  3. Wiring: Connect the power supply, input signals, and output relays according to the wiring diagram provided in the manual.

Operating Instructions

  1. Power On/Off: Press the [POWER] button to turn the TM-630S on or off.
  2. Setting the Time: Use the [▲] and [▼] buttons to set the desired time. The time can be set in seconds, minutes, hours, or days.
  3. Selecting the Control Mode: Choose one of the four control modes (A, B, C, or D) using the [MODE] button.
  4. Setting the Relay Outputs: Configure the relay outputs according to the desired application.

Control Modes

The TM-630S offers four control modes:

  1. Mode A (Interval Mode): The relay output is activated for a set time interval.
  2. Mode B (Delay Mode): The relay output is activated after a set delay time.
  3. Mode C (Cycle Mode): The relay output is activated for a set time interval and then deactivated for another set time interval.
  4. Mode D (Loop Mode): The relay output is activated for a set time interval and then deactivated for another set time interval, repeating the cycle.

Analog Output (Optional)

The TM-630S can be equipped with an analog output (0-10V or 4-20mA) for monitoring the timer's status.

Communication Interface

The TM-630S can be connected to a computer or a control system using the RS485 or MODBUS communication interface.

Maintenance and Troubleshooting

  1. Cleaning: Regularly clean the TM-630S to prevent dust and debris accumulation.
  2. Error Messages: Consult the manual for error messages and troubleshooting procedures.
  3. Replacement of Fuses: Replace fuses according to the manual's instructions.

Technical Specifications

Conclusion

The Sinotimer TM-630S is a versatile and reliable timer controller suitable for various industrial and commercial applications. This manual provides comprehensive information on the installation, operation, and maintenance of the TM-630S, ensuring optimal performance and longevity.


4. Wiring Instructions (Critical)

WARNING: Risk of Electric Shock. Always turn off the main power before wiring.

The TM-630S usually features a 3-Wire Terminal Block:

  1. L (Line/In): Connect the Live wire from your mains power supply.
  2. N (Neutral): Connect the Neutral wire from your mains supply AND the Neutral wire of your appliance/load.
    • Note: The timer requires power to run, so it needs a permanent Neutral connection.
  3. L (Load/Out): Connect the Live wire going to your appliance.

Wiring Diagram Concept:

[Mains Power]
   Live (L) -------------> Terminal 1 (L In)
   Neutral (N) ----------> Terminal 2 (N)
[Appliance/Load]
   Live Wire -----------> Terminal 3 (L Out)
   Neutral Wire --------> Connected directly to Mains Neutral (Terminal 2)

4.1 Reset the Timer

Press RST with a pointed object. The display will clear and show initial time (12:00 AM or 00:00).

List of Typical Modes (17 Functions)

The "mode" refers to how the timer applies the ON/OFF times. You select the mode by pressing PROG and holding the up/down arrows until you see a specific symbol.

Here is the key interpretation:

| Mode | Display Symbol | Meaning | Typical Use | | :--- | :--- | :--- | :--- | | Mode 1 | Single block | Timer cycles once at set time | Delayed start | | Mode 2 | Recurring arrow | Continuous cycles (ON for X min, OFF for Y min) | Hydroponic pumps | | Mode 3 | 24H + cycle | 24-hour cycle with specific ON/OFF times | Street lights | | Mode 4-17 | Weekday sequences | Different programs for different days | Office lights (M-F, Sa-Su separate) |

The most common mode for beginners is Mode 3 – Simple 24-hour repeating timer with one ON time and one OFF time.

Example: Turn a light ON at 6:00 PM and OFF at 6:00 AM daily.

  1. Set mode to "24H" (Mode 3).
  2. Program 1ON for 18:00.
  3. Program 1OFF for 06:00 (next day – the timer automatically handles crossover).
  4. Set days to "All" (Mo Tu We Th Fr Sa Su).
  5. Exit programming. Ensure unit is in AUTO.

2. Button Functions


Downloading the Official Sinotimer TM-630S Manual PDF

While this guide covers 99% of usage, you may want the original 2-page pamphlet. You can download the Sinotimer TM-630S manual in PDF format from:

Part 1: First Look & Technical Specifications

Before programming, you must understand what the device can do. The Sinotimer TM-630S is a microcomputer-based time switch with a liquid crystal display (LCD). 6-digit LED display 16 timing ranges (0

4. Initial Setup

Advanced Feature: Setting the Time Range (S, M, H)

This is the most overlooked part of the Sinotimer TM-630S manual. If you set P1 to 100 with time base S, you get 100 seconds. But if you meant 100 minutes (1.66 hours), you need to change the base before setting P1.

Pro tip: The maximum full time is 9999 hours, which equals 416 days. This is useful for long-term maintenance timers.