Wittmann Tempro Plus D 360 Manual ~repack~

The Wittmann Tempro Plus D 360 is a high-performance, pressurized water temperature control unit (TCU) designed for industrial mold temperature regulation, capable of reaching supply temperatures up to (

While a full narrative "story" isn't standard for industrial manuals, the "life cycle" and operational logic of this unit follow a specific sequence: 1. Setup & First Fill To begin operation, the unit requires a "First Fill."

Access: Log in using the settings button with the default user password 1220.

Adjustment: In the "Service" tab under the "121 times" menu, you can set the "first filling max field" to ensure the unit primes correctly. 2. Core Operation Features

Visual Control: The touch-screen uses a color-coded mold symbol: Green (within tolerance), Red (too hot), and Blue (too cold).

Precision: It utilizes a microprocessor controller with an accuracy of .

Safety: Standard equipment includes automatic pump rotation detection, pressure monitoring, and audible alarms. 3. The Shutdown "Story" (Critical Maintenance)

The most important part of the unit's "story" is its shutdown to prevent equipment failure.

The Risk: Abruptly cutting power while the heater is active can cause permanent damage. Wittmann Tempro Plus D 360 Manual

Proper Sequence: Use the Fn (Function) key to select a cooling mode like "Cool Down Stop" or "Mold Purge Stop".

Completion: A snowflake icon appears during the cooldown. Once the return temperature reaches the safe set value and the pump stops, the unit enters an "Off" state and can then be safely disconnected.

For official documentation, you can visit the Wittmann Group Download Center to find specific PDF manuals and technical data sheets. Temperature Controllers - WITTMANN Group

The Wittmann Tempro Plus D 360 (often referred to as part of the broader pressurized series or associated with high-output L-series models) is a high-performance temperature control unit (TCU) designed for precise mold tempering in injection molding. These units are engineered for applications requiring high flow rates and reliable temperature stability up to 140°C or 160°C, depending on the specific model configuration.

For official documentation, you can browse the WITTMANN Download Center for current brochures and manuals. 1. Key Technical Specifications

The Tempro Plus D series is known for its "Plus" features, which include advanced touchscreen controls and reinforced components for industrial durability.

Controller Accuracy: Microprocessor-based control with ± 0.2 °C accuracy.

Heating Power: Typically 9 kW to 12 kW as standard, with options for larger heaters (up to 36 kW in XL models) for rapid preheating. The Wittmann Tempro Plus D 360 is a

Cooling System: Available with direct or indirect cooling. Direct cooling offers exceptionally high capacity for rapid thermal reduction.

Pumps: Maintenance-free magnetically coupled pumps are standard for pressurized units, preventing leaks and ensuring long-term reliability. 2. Operation and Control Interface

The unit features a 5.7" color touchscreen powered by Windows CE, providing intuitive navigation.

Visual Monitoring: A mold symbol on the screen changes color based on temperature status: Green (within tolerance), Red (too hot), and Blue (too cold).

Quick Selection: Frequently used operating modes can be accessed via touch fields at the bottom of the screen.

Smart Logging: Users can export error logs to a USB stick. To access the error buffer, navigate to the Service tab and enter the default user password '1220'. TEMPRO MOld TEMPERaTuRE COnTROllERs - WITTMANN Group

While a single comprehensive PDF manual for the Wittmann Tempro Plus D 360 is often restricted to owners via the official Wittmann Download Center, the following operational and maintenance details are standard for this series: Common Operations

Adjusting Fill Time: Log in using password "1220". Navigate to Settings > Service > 121 times > Circuits > First filling max field to input a new value. Wittmann Tempro Plus D 360 Manual 3

Safe Shutdown: Never disconnect power while the heater is active. Press the Fn key to view functions.

Select a cooling mode (e.g., Cool Down Stop or Mold Purge Stop).

Wait for a snowflake icon to appear and for the return temperature to reach the set value before turning off the main disconnect.

Visual Status: The mold symbol on the touchscreen indicates status: Green (within tolerance), Red (too hot), or Blue (too cold). Standard Specifications

Microprocessor Control: Features ± 0.2 °C accuracy with self-optimizing capabilities.

Equipment: Standard units include automatic filling, pump rotation detection, dry-run protection, and a potential-free alarm contact.

Connectivity: Equipped with a Wittmann 4.0 interface and sockets for external PT 100 sensors. Maintenance Resources

The Wittmann Group Website provides high-level brochures and technical catalogs that outline pump characteristics and cooling capacities for the Tempro Plus D line. TEMPRO plus D TCU - Adjusting First Fill Time


Wittmann Tempro Plus D 360 Manual

3. Technical Specifications

| Parameter | Value | |-----------|-------| | Temperature range | +20°C … +140°C (standard) / +160°C (optional) | | Heating capacity | 9 kW (3 x 3 kW stainless steel immersion heaters) | | Cooling type | Direct injection (water-to-water) | | Cooling water requirement | 10–40°C, 2–6 bar, flow rate ≥ 40 L/min | | Pump type | Centrifugal, stainless steel impeller | | Max. pump pressure | 4.8 bar at 0 L/min; 2.5 bar at 60 L/min | | Flow measurement | Turbine wheel sensor (4–20 mA output) | | Tank volume | 3.6 liters (stainless steel, insulated) | | Electrical supply | 400V ±10%, 3-phase, 50/60 Hz, 16 A (CEE plug) | | Control system | Wittmann R8.2 controller with 5.7” color touchscreen |

Part 5: Navigating the Controller Interface (The "Plus" Logic)

This is where the Wittmann Tempro Plus D 360 manual differs from generic TCU guides. The "Plus" controller has a hierarchical menu.